Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 1636 - 1650 of 2470 items found.

  • Variable Frequency Modules

    9554-( ) - Solar Electronics Company

    Utilizing the high voltage power source in the Model 9354-1 Universal Transient Generator, four individual modules can be connected to provide tuning of damped sine waves from 10 KHz to 50 MHz. A fifth module is available which, when used in conjunction with the Model 9354-1, provides 20% frequency steps from 30 MHz to 100 MHz

  • Precision Source/Measure Unit (SMU)

    B2900A Series - Keysight Technologies

    The Keysight B2900 Series precision source measure unit (SMU) provides superior performance and usability at a reasonable price. These compact benchtop SMUs enable you to quickly take various I-V (current versus voltage) measurements requiring high resolution and accuracy. Easily view results on the user-friendly, color LCD graphic interface without changing connections.

  • NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module

    785043-01 - NI

    4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module

    784788-01 - NI

    4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • Precision Source / Measure Units (SMU)

    B2900 Series - Keysight Technologies

    The Keysight B2900 Series precision source measure unit (SMU) provides superior performance and usability at a reasonable price. These compact benchtop SMUs enable you to quickly take various I-V (current versus voltage) measurements requiring high resolution and accuracy. Easily view results on the user-friendly, color LCD graphic interface without changing connections.

  • Dual Wide Angle Scale Instrument

    LS-110 DI (AC/DC) - Standard Electric Works Co., Ltd

    ● Analog and digital display to provide the ultimate in readability of power and control parameters● Drop-in replacement for upgrade of existing controls and switchgear panels● Rugged switchboard style case and IP54 rated cover● High-intensity LED digital displays with high reliability analog movements● Safety models for AC or DC voltage and current, with custom scales and dials available as options

  • Hipot Current Calibration Load Resistors

    HPRS-HIPOT-LOAD - IET Labs

    The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.

  • Sonar

    CTS Valpey Corp.

    Piezo elements are used in military and commercial sonar systems for position finding activities. Location of surface and subsurface vessels, depth measurement, surveying, fish location, and communication are several of the more common sonar applications. Piezoelectric ceramic materials have high bandwidth and can quickly respond by applying high force at low power levels. These materials are generally unaffected by environmental factors such as humidity and temperature. CTS materials can be formed to customer specifications and are available in a wide range of geometries with dimensions up to 150 mm or thicknesses less than 100 microns. Our materials sustain high levels of drive voltage and provide excellent coupling factors in sonar applications.

  • Voltage Controlled Oscillators

    Pasternack Enterprises, Inc.

    a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.

  • Voltage Variable Attenuators

    Pasternack Enterprises, Inc.

    a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.

  • LISN & Voltage Probes

    Laplace Instruments Ltd.

    All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. The Voltage Probe requirement is covered by our PLIP (Power LIne Interference Probe). This fully meets the requirements of CISPR16, but has additional features:*Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser!*Shrouded safety clips for attachment to the line to be measured.*Filtered frequency response matched to Band A and B.*Current limiting on the output.*Visual indication of high voltage input.

  • Bench Power Supply, DC, Single, Adjustable, 1 Output, 1 V, 36 V, 0 A, 3 A

    72-8345A - Tenma

    Switch Mode Laboratory DC Power Supplies Precision adjustable supply provides adjustable 1~36VDC output with adjustable current limiting from 0~3A. It is ideal for test, measurement and service applications where tight voltage and current regulation are critical. Highly efficient switch mode design delivers outstanding performance from an extremely compact footprint. Unique separate output ON/OFF control allows voltage and current setting, with the supply output turned off. Part of a Complete Series, this slim supply occupies little bench space while providing very high precision and 90W of continuous output.

  • Wind Direction Sensor

    ENVIROMUX-EWDS - Network Technologies Inc

    Balanced wind direction vane with a near-zero friction bearing and a high accuracy magnetic angle sensor to provide precision wind direction. Sensor range: full 360 degrees , zero deadband. Accuracy: ±1.8 degrees. Resolution: 12 bit or 0.025 degrees. Directional Vane approximately 8 inches (203 millimeters). 3 wire flying leads, 25-feet (7.6-meter). Supply voltage: 4.5 to 5.5 VDC. Current: 15 mA typical. Output: 5 to 95% of input voltage (0.25 to 4.75VDC). Requires the ENVIROMUX-S5VDC-5V to operate with ENVIROMUX-2D/5D/16D. Maximum cable length: 1000 ft (305m)

  • Capacitive H.V. Detectors (Contact)

    213 HVD~226 HVD - Standard Electric Works Co., Ltd

    ● Excellent shock resistance.● Rugged nylon moulding.● Auto on (when voltage detected).● Excellent drop resistance.● Good vibration resistance.● Loud sound alarm indication.● Built-in proving and self-test circuit.● High bright color-coded LEDS.● Works from standard 9V battery.● Interchangeable contact electrode.● Use in all whether conditions.● Compatible with all link sticks.● Lightweight, robust & compact.● Models available from 11kV to 132kV.● Suitable for indoor and outdoor use.● Self(auto on) or manual arming.● Easy access to batteries.● Customized threshold on demand.● Auto off (if no voltage detected).● Waterproof design, protection class : IP65.

  • Oil Immersed Test Transformer

    SG-YD - Wuhan Sangao Electrical Test Installations Limit Co.

    AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.

Get Help